13.1. Acronyms
13.1.1. Intuitive Surgical
- ISI
Intuitive Surgical Inc., now known simply as Intuitive (https://wwww.intuitive.com)
- Classic
First generation da Vinci. The original da Vinci research kit is based on the Classic. Also known as Standard. Patient cart came with either 2 or 3 PSMs.
- Standard
See Classic.
- S
Second generation da Vinci. New patient cart (PSMs, ECM, SUJs…), but surgeon console (MTMs, pedals, display…) are similar to first generation.
- Si
Third generation da Vinci (see da Vinci Si). New surgeon console (MTMs, dual console, display, simulator…). Patient cart is similar to second generation. Supported by the dRAC based dVRK Si controllers.
- Si-E
Same as Si but with only two PSMs on the patient cart (PSM3 not included).
- Xi
Fourth generation da Vinci. New setup joints, new arm to replace both PSMs and ECM (now known as USMs) can be used to hold tools or camera. Surgeon console and stereo display similar to Si.
- X
Similar to Si but with Xi patient side arms.
- 5
Latest generation, new surgeon console and patient cart based on Xi systems. The da Vinci 5 also introduce instruments with force sensing to provide haptic feedback to the operator.
- PSM
Patient Side Manipulator, 2 to 3 on a full da Vinci system. Mechanically identical, they’re called PSM1, PSM2, PSM3 (see Classic PSM and Si PSM).
- MTM
Master Tool Manipulator, 2 on a full da Vinci system (4 with dual console on Si/Xi system). Not mechanically identical, last joints are different for left and right arms, they’re called MTML and MTMR (see MTM).
- ECM
Endoscopic Camera Manipulator, 1 on real da Vinci system (see Classic ECM and Si ECM).
- SUJ
Setup Joints, patient cart with 4 passive arms to hold active ECM and PSMs. Some early versions (Standard, S, Si) came with only three passive arms (missing PSM3). See Classic SUJ and Si SUJ.
- HRSV:
High Resolution Stereo Viewer. At least 3 versions exist, 640x480 CRT (Standard and S), 1024x768 CRT (S HD), LCD (Si/Xi/5). The Research Kit initially came with the CRT 640x480, recent sites should receive the console from S HD systems. See Video.
- CCU
Camera Control Unit. The two boxes in the vision cart that are connected to the endoscope cameras. These usually have either an NTSC or SDI output for frame grabbers. See Video.
- Tray
Foot pedal tray: foot pedals including clutch, camera, camera focus, bi and mono (or coag). See Pedals.
13.1.2. dVRK
13.1.2.1. General
- dVRK
da Vinci Research Kit
- JHU
- LCSR
Laboratory for Computational Sensing and Robotics (at Johns Hopkins)
- cisst
Computer-Integrated Surgical Systems and Technology: NSF ERC CISST and cisst libraries
- SAW
Surgical Workstation Assistant: components based on cisst libraries
- CRTK
- ROS
Robotic Operating System (see ROS 1 and ROS 2 compilation)
13.1.2.2. dVRK specific
All boards are designed by JHU and built specifically for the dVRK unless mentioned otherwise.
- QLA
Motor power board, Quad Linear Amplifier, JHU designed board with power for up to 4 axes (see QLA board). Used in Classic arm controllers (2 per controller) and Classic SUJ controller.
- dRAC
Motor power board 10 PWM power lines, JHU designed board to power up to 7 motors and 3 brakes (see dRAC board). Used in Si controllers.
- FPGA
Logic board designed by JHU, mated with QLAs or dRAC (see FPGA board). Provides 2 FireWire adapters to daisy-chain and connect to PC. Versions 2+ also includes an Ethernet adapter. Version 3+ uses a newer FPGA, 2 FireWire and 2 Ethernet adapters, a dual-core ARM processor boots from a micro-SD card (see FPGA versions).
- QLA-FPGA
Board set including a QLA and FPGA board. Used in the Classic arm controllers, up to CA9 (see controller versions).
- DQLA
Dual QLA setup with a single FPGA board (version 3+). Used in the Classic arm controllers after CA9 (see controller versions).
- Firmware
In most cases, refers to embedded software running on the FPGA logic board. For Si systems can also refer to the ESSJ or ESPM boards. See dVRK firmware.
- dMIB
da Vinci Manipulator Interface Board, board designed to interface between the ISI manipulators using an ITT Cannon plus a foot pedal connector and the QLA-FPGA connectors (SCSI and RS cables). Used in Classic arm controllers (see also dMIB I/Os).
- dSIB
da Vinci Setup joints Interface Board. Used in Classic SUJ controllers.
- ESPM
Board manufactured by ISI, embedded in S/Si PSMs and ECMs. The dVRK uses the ESPM but with a custom firmware (see ESPM).
- ESPM programmer
Board used to boot a Si PSM or ECM with a custom dVRK firmware (obsolete as of August 2026, replaced by ESXX programmer).
- ESSJ
Board manufactured by ISI, embedded in the Si SUJ patient cart to read the joint potentiometers. The dVRK uses the ESSJ with a custom firmware (see ESSJ).
- ESXX programmer
Board used to flash custom dVRK firmware onto ESPM and ESSJ FPGA boards (see ESXX programmer). Replaces the obsolete ESPM programmer.
- dSIB-Si
Adapter board used to connect the dVRK-Si controller to a single arm and its setup joints at the base of the patient cart (either PSM or ECM). See dSIB-Si and Si setup joints.
- dSIB-Z-Si
Adapter board used to read the linear potentiometers for all four translation stages on the Si patient cart SUJs. See Si setup joints.
- LVDS
Low-voltage differential signaling (LVDS) is a signaling method used for high-speed transmission of binary data over copper. This is used to communicate between the ESPM, ESSJ and dVRK-Si controller (see Si connections).